| FHQ100CBVEB / RZQG71L9V1B | FHQ35CBVEB / FHQ35CBVEB / FHQ35CBVEB / RZQG71L9V1B | FHQ50CBVEB / FHQ50CBVEB / RZQG71L9V1B | FHQ71CBVEB / RZQG71L9V1B | FHQ35CBVEB / FHQ35CBVEB / RZQG71L9V1B | FHQ100CBVEB / RZQG100L9V1B | FHQ35CBVEB / FHQ35CBVEB / FHQ35CBVEB / RZQG100L9V1B | FHQ50CBVEB / FHQ50CBVEB / FHQ50CBVEB / RZQG100L9V1B | FHQ50CBVEB / FHQ50CBVEB / RZQG100L9V1B | FHQ140CBVEB / RZQG100L9V1B | FHQ35CBVEB / FHQ35CBVEB / FHQ35CBVEB / FHQ35CBVEB / RZQG100L9V1B | FHQ71CBVEB / FHQ71CBVEB / RZQG100L9V1B | FHQ71CBVEB / FHQ71CBVEB / RZQG125L9V1B | FHQ125CBVEB / RZQG125L9V1B | FHQ50CBVEB / FHQ50CBVEB / FHQ50CBVEB / RZQG125L9V1B | FHQ140CBVEB / RZQG125L9V1B | FHQ35CBVEB / FHQ35CBVEB / FHQ35CBVEB / FHQ35CBVEB / RZQG125L9V1B | FHQ60CBVEB / FHQ60CBVEB / RZQG125L9V1B | FHQ140CBVEB / RZQG140L9V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Chladiaci výkon | Men. | kW | 6.8 | 9.5 | 12.0 | 13.4 | ||||||||||||||||
| Chladenie | SEER | 6.95 | 5.10 | 5.10 | 6.86 | 5.10 | 6.11 | 5.10 | 5.10 | 5.10 | 6.11 | 5.10 | 5.10 | 5.10 | 6.01 | 5.10 | 6.01 | 5.10 | 5.10 | |||
| Ročná spotreba energie | kWh/a | 343 | 467 | 467 | 347 | 467 | 545 | 652 | 652 | 652 | 545 | 652 | 652 | 824 | 699 | 824 | 699 | 824 | 824 | |||
| Výkon | P návrh | kW | 6.80 | 6.80 | 6.80 | 6.80 | 6.80 | 9.50 | 9.50 | 9.50 | 9.50 | 9.50 | 9.50 | 9.50 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | ||
| Trieda energetickej účinnosti | A++ | B | B | A++ | B | A++ | B | B | B | A++ | B | B | B | A+ | B | A+ | B | B | ||||
| Vykurovanie (stredné klim. pásmo) | Výkon | P návrh | kW | 7.60 | 6.00 | 6.00 | 7.60 | 6.00 | 11.30 | 11.30 | 11.30 | 11.30 | 11.30 | 11.30 | 11.30 | 12.71 | 14.13 | 12.71 | 14.13 | 12.71 | 12.71 | |
| SCOP/A | 4.32 | 3.80 | 3.80 | 4.32 | 3.80 | 4.61 | 3.80 | 3.80 | 3.80 | 4.61 | 3.80 | 3.80 | 3.80 | 4.23 | 3.80 | 4.23 | 3.80 | 3.80 | ||||
| Trieda energetickej účinnosti | A+ | A | A | A+ | A | A++ | A | A | A | A++ | A | A | A | A+ | A | A+ | A | A | ||||
| Ročná spotreba energie | kWh/a | 2,463 | 2,211 | 2,211 | 2,463 | 2,211 | 3,432 | 4,164 | 4,164 | 4,164 | 3,432 | 4,164 | 4,164 | 4,683 | 4,677 | 4,683 | 4,677 | 4,683 | 4,683 | |||
| Nominálna účinnosť | Ročná spotreba energie | kWh | 890 | 1,245 | 1,790 | 2,025 | ||||||||||||||||
| EER | 3.82 | 3.81 | 3.35 | 3.31 | ||||||||||||||||||
| COP | 4.13 | 4.15 | 3.89 | 3.63 | ||||||||||||||||||
| Smernica o energetickom označovaní | Chladenie | A | A | A | A | |||||||||||||||||
| Vykurovanie | A | A | A | A | ||||||||||||||||||
| Vykurovací výkon | Men. | kW | 7.5 | 10.8 | 13.5 | 15.5 | ||||||||||||||||
| Poznámky | (1) - Ročná spotreba energie je podľa Smernice o energetickom označení 2002/31/ES | (1) - EER/COP podľa Eurovent 2012 na použitie len mimo EÚ | (1) - EER/COP podľa Eurovent 2012 na použitie len mimo EÚ | (1) - EER/COP podľa Eurovent 2012 na použitie len mimo EÚ | ||||||||||||||||||
| (2) - Hodnoty SEER a SCOP sú podľa normy EN 14825 | (2) - Nominálna účinnosť: chladenie pri 35°/27° nomin. záťaž, vykurovanie pri 7°/20° nomin. záťaž | (2) - Nominálna účinnosť: chladenie pri 35°/27° nomin. záťaž, vykurovanie pri 7°/20° nomin. záťaž | (2) - Nominálna účinnosť: chladenie pri 35°/27° nomin. záťaž, vykurovanie pri 7°/20° nomin. záťaž | |||||||||||||||||||