| EHVX08S18EA6V / ERGA08EAV3H7 | EHVX08S18EJ6V / ERGA08EAV3H7 | EHVX08S23EA6V / ERGA08EAV3H7 | EHVX08S23EJ6V / ERGA08EAV3H7 | |||||
|---|---|---|---|---|---|---|---|---|
| Vykurovací výkon | Men. | kW | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | ||
| Chladiaci výkon | Men. | kW | 6.25 (1), 5.44 (2) | 6.25 (1), 5.44 (2) | 6.25 (1), 5.44 (2) | 6.25 (1), 5.44 (2) | ||
| Vstup napájania | Kúrenie | Men. | kW | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | |
| Chladenie | Men. | kW | 1.16 (1), 1.73 (2) | 1.16 (1), 1.73 (2) | 1.16 (1), 1.73 (2) | 1.16 (1), 1.73 (2) | ||
| Príkon | Teplá pitná voda od 10°C do 50°C | Nom. ot. | kWh | 2.48 | 2.48 | 3.01 | 3.01 | |
| Doba ohrevu od 10°C do 50°C | hod. | 1h 28 min | 1h 28 min | 1 h 40 min | 1 h 40 min | |||
| COP | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | ||||
| EER | 5.40 (1), 3.14 (2) | 5.40 (1), 3.14 (2) | 5.40 (1), 3.14 (2) | 5.40 (1), 3.14 (2) | ||||
| Ohrev teplej pitnej vody | Všeobecné | Uvedený záťažový profil | L | L | XL | XL | ||
| Priemerná klíma | Trieda energetickej účinnosti ohrevu vody | A+ | A+ | A+ | A+ | |||
| Vykur. priestoru | Priemerné podnebie – výstup vody 55°C | Všeobecné | SCOP | 3.35 | 3.35 | 3.35 | 3.35 | |
| Trieda sezónnej účinnosti vykurovania priestoru | A++ | A++ | A++ | A++ | ||||
| Priemerné podnebie – výstup vody 35°C | Všeobecné | SCOP | 4.61 | 4.61 | 4.61 | 4.61 | ||
| Trieda sezónnej účinnosti vykurovania priestoru | A+++ | A+++ | A+++ | A+++ | ||||
| Rozsah energetickej účinnosti | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | ||||
| Poznámky | (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) | (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) | (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) | (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) | ||||
| (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) | (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) | (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) | (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) | |||||