EHVX11S18CB3V / ERHQ011BAW1 EHVX11S26CB9W / ERHQ011BAW1 EHVX16S18CB3V / ERHQ014BAW1 EHVX16S26CB9W / ERHQ014BAW1 EHVX16S18CB3V / ERHQ016BAW1 EHVX16S26CB9W / ERHQ016BAW1
Ohrev tep. vody Všeobecné Uvedený záťažový profil   L XL L   L XL
  Priemerná klíma Trieda energetickej účinnosti ohrevu vody   A A A   A A
COP 4.30 (1), 3.39 (2) 4.30 (1), 3.39 (2) 4.24 (1), 3.22 (2) 4.24, 3.22 4.20 (1), 3.22 (2) 4.20 (1), 3.22 (2)
Chladiaci výkon Men. kW 15.1 (1), 11.7 (2) 15.1 (1), 11.7 (2) 16.1 (1), 12.6 (2)   16.8 (1), 13.1 (2) 16.8 (1), 13.1 (2)
EER 3.32 (1), 2.72 (2) 3.32 (1), 2.72 (2) 2.96 (1), 2.47 (2) 2.96, 2.47 2.72 (1), 2.29 (2) 2.72 (1), 2.29 (2)
Vykurovací výkon Men. kW 11.3 (1), 11.0 (2) 11.3 (1), 11.0 (2) 14.5 (1), 13.6 (2)   16.1 (1), 15.1 (2) 16.1 (1), 15.1 (2)
Vstup napájania Chladenie Men. kW 4.53 (1), 4.31 (2) 4.53 (1), 4.31 (2) 5.43 (1), 5.08 (2)   6.16 (1), 5.73 (2) 6.16 (1), 5.73 (2)
  Kúrenie Men. kW 2.63 (1), 3.24 (2) 2.63 (1), 3.24 (2) 3.42 (1), 4.21 (2)   3.82 (1), 4.69 (2) 3.82 (1), 4.69 (2)
Poznámky (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C)
  (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C)
  (3) - Tamb 35 °C - LWE 7 °C (DT = 5 °C) (3) - Tamb 35 °C - LWE 7 °C (DT = 5 °C) (3) - Tamb 35 °C - LWE 7 °C (DT = 5 °C) (3) - Tamb 35 °C - LWE 7 °C (DT = 5 °C) (3) - Tamb 35 °C - LWE 7 °C (DT = 5 °C) (3) - Tamb 35 °C - LWE 7 °C (DT = 5 °C)
  (4) - Tamb 35°C - LWE 18℃ (DT=5°C) (4) - Tamb 35°C - LWE 18℃ (DT=5°C) (4) - Tamb 35°C - LWE 18℃ (DT=5°C) (4) - Tamb 35°C - LWE 18℃ (DT=5°C) (4) - Tamb 35°C - LWE 18℃ (DT=5°C) (4) - Tamb 35°C - LWE 18℃ (DT=5°C)
  (5) - DB/WB 7°C/6°C-LWC 35°C(DT=5°C) (5) - DB/WB 7°C/6°C-LWC 35°C(DT=5°C) (5) - DB/WB 7°C/6°C-LWC 35°C(DT=5°C) (5) - DB/WB 7°C/6°C-LWC 35°C(DT=5°C) (5) - DB/WB 7°C/6°C-LWC 35°C(DT=5°C) (5) - DB/WB 7°C/6°C-LWC 35°C(DT=5°C)
  (6) - DB/WB 7 °C/6 °C - LWC 45 °C (Dt = 5 °C) (6) - DB/WB 7 °C/6 °C - LWC 45 °C (Dt = 5 °C) (6) - DB/WB 7 °C/6 °C - LWC 45 °C (Dt = 5 °C) (6) - DB/WB 7 °C/6 °C - LWC 45 °C (Dt = 5 °C) (6) - DB/WB 7 °C/6 °C - LWC 45 °C (Dt = 5 °C) (6) - DB/WB 7 °C/6 °C - LWC 45 °C (Dt = 5 °C)
Vykurovací výkon Men. kW       14.5, 13.6
Chladiaci výkon Men. kW       16.1, 12.6
Vstup napájania Kúrenie Men. kW       3.42, 4.21
  Chladenie Men. kW       5.43, 5.08
Ohrev teplej pitnej vody Všeobecné Uvedený záťažový profil         XL
  Priemerná klíma Trieda energetickej účinnosti ohrevu vody         A
Vykur. priestoru Priemerné podnebie – výstup vody 55°C Všeobecné SCOP         2.80
      Trieda sezónnej účinnosti vykurovania priestoru         A+
  Priemerné podnebie – výstup vody 35°C Všeobecné SCOP         3.34
      Trieda sezónnej účinnosti vykurovania priestoru         A+