Specifications Table for EKHBX-B / ERLQ-CV3

EKHBX016BA9T1 / ERLQ011CAV3 EKHBX016BA6T1 / ERLQ011CAV3 EKHBX016BA6WN / ERLQ011CAV3 EKHBX016BA6V3 / ERLQ011CAV3 EKHBX016BA3V3 / ERLQ011CAV3 EKHBX016BA9T1 / ERLQ014CAV3 EKHBX016BA6V3 / ERLQ014CAV3 EKHBX016BA6T1 / ERLQ014CAV3 EKHBX016BA9WN / ERLQ014CAV3 EKHBX016BA3V3 / ERLQ014CAV3 EKHBX016BA6WN / ERLQ014CAV3 EKHBX016BA9T1 / ERLQ016CAV3 EKHBX016BA6T1 / ERLQ016CAV3 EKHBX016BA3V3 / ERLQ016CAV3 EKHBX016BA6V3 / ERLQ016CAV3 EKHBX016BA6WN / ERLQ016CAV3 EKHBX016BA9WN / ERLQ016CAV3 EKHBX016BA9WN / ERLQ011CAV3
Vykurovací výkon Men. kW 11.20 (1), 10.98 (2) 11.20 (1), 10.98 (2) 11.20 (1), 10.98 (2) 11.20 (1), 10.98 (2) 11.20 (1), 10.98 (2) 14.00 (1), 13.57 (2) 14.00 (1), 13.57 (2) 14.00 (1), 13.57 (2) 14.00 (1), 13.57 (2) 14.00 (1), 13.57 (2) 14.00 (1), 13.57 (2) 16.00 (1), 15.20 (2) 16.00 (1), 15.20 (2) 16.00 (1), 15.20 (2) 16.00 (1), 15.20 (2) 16.00 (1), 15.20 (2) 16.00 (1), 15.20 (2) 11.20 (1), 10.98 (2)
  Max. kW 8.81 (3), 8.16 (4) 8.81 (3), 8.16 (4) 8.81 (3), 8.16 (4) 8.81 (3), 8.16 (4) 8.81 (3), 8.16 (4) 11.65 (3), 10.96 (4) 11.65 (3), 10.96 (4) 11.65 (3), 10.96 (4) 11.65 (3), 10.96 (4) 11.65 (3), 10.96 (4) 11.65 (3), 10.96 (4) 12.30 (3), 11.35 (4) 12.30 (3), 11.35 (4) 12.30 (3), 11.35 (4) 12.30 (3), 11.35 (4) 12.30 (3), 11.35 (4) 12.30 (3), 11.35 (4) 8.81 (3), 8.16 (4)
Chladiaci výkon Men. kW 15.05 (1), 11.72 (2) 15.05 (1), 11.72 (2) 15.05 (1), 11.72 (2) 15.05 (1), 11.72 (2) 15.05 (1), 11.72 (2) 16.06 (1), 12.55 (2) 16.06 (1), 12.55 (2) 16.06 (1), 12.55 (2) 16.06 (1), 12.55 (2) 16.06 (1), 12.55 (2) 16.06 (1), 12.55 (2) 16.76 (1), 13.12 (2) 16.76 (1), 13.12 (2) 16.76 (1), 13.12 (2) 16.76 (1), 13.12 (2) 16.76 (1), 13.12 (2) 16.76 (1), 13.12 (2) 15.05 (1), 11.72 (2)
Príkon Kúrenie Men. kW 2.41 (1), 3.15 (2) 2.41 (1), 3.15 (2) 2.41 (1), 3.15 (2) 2.41 (1), 3.15 (2) 2.41 (1), 3.15 (2) 3.14 (1), 4.12 (2) 3.14 (1), 4.12 (2) 3.14 (1), 4.12 (2) 3.14 (1), 4.12 (2) 3.14 (1), 4.12 (2) 3.14 (1), 4.12 (2) 3.72 (1), 4.60 (2) 3.72 (1), 4.60 (2) 3.72 (1), 4.60 (2) 3.72 (1), 4.60 (2) 3.72 (1), 4.60 (2) 3.72 (1), 4.60 (2) 2.41 (1), 3.15 (2)
    Max. kW 3.43 (3), 4.05 (4) 3.43 (3), 4.05 (4) 3.43 (3), 4.05 (4) 3.43 (3), 4.05 (4) 3.43 (3), 4.05 (4) 4.86 (3), 5.57 (4) 4.86 (3), 5.57 (4) 4.86 (3), 5.57 (4) 4.86 (3), 5.57 (4) 4.86 (3), 5.57 (4) 4.86 (3), 5.57 (4) 5.40 (3), 6.25 (4) 5.40 (3), 6.25 (4) 5.40 (3), 6.25 (4) 5.40 (3), 6.25 (4) 5.40 (3), 6.25 (4) 5.40 (3), 6.25 (4) 3.43 (3), 4.05 (4)
  Chladenie Men. kW 4.44 (1), 4.22 (2) 4.44 (1), 4.22 (2) 4.44 (1), 4.22 (2) 4.44 (1), 4.22 (2) 4.44 (1), 4.22 (2) 5.33 (1), 5.00 (2) 5.33 (1), 5.00 (2) 5.33 (1), 5.00 (2) 5.33 (1), 5.00 (2) 5.33 (1), 5.00 (2) 5.33 (1), 5.00 (2) 6.06 (1), 5.65 (2) 6.06 (1), 5.65 (2) 6.06 (1), 5.65 (2) 6.06 (1), 5.65 (2) 6.06 (1), 5.65 (2) 6.06 (1), 5.65 (2) 4.44 (1), 4.22 (2)
COP 4.66 (1), 3.48 (2), 2.57 (3), 2.01 (4) 4.66 (1), 3.48 (2), 2.57 (3), 2.01 (4) 4.66 (1), 3.48 (2), 2.57 (3), 2.01 (4) 4.66 (1), 3.48 (2), 2.57 (3), 2.01 (4) 4.66 (1), 3.48 (2), 2.57 (3), 2.01 (4) 4.46 (1), 3.29 (2), 2.40 (3), 1.97 (4) 4.46 (1), 3.29 (2), 2.40 (3), 1.97 (4) 4.46 (1), 3.29 (2), 2.40 (3), 1.97 (4) 4.46 (1), 3.29 (2), 2.40 (3), 1.97 (4) 4.46 (1), 3.29 (2), 2.40 (3), 1.97 (4) 4.46 (1), 3.29 (2), 2.40 (3), 1.97 (4) 4.30 (1), 3.29 (2), 2.28 (3), 1.82 (4) 4.30 (1), 3.29 (2), 2.28 (3), 1.82 (4) 4.30 (1), 3.29 (2), 2.28 (3), 1.82 (4) 4.30 (1), 3.29 (2), 2.28 (3), 1.82 (4) 4.30 (1), 3.29 (2), 2.28 (3), 1.82 (4) 4.30 (1), 3.29 (2), 2.28 (3), 1.82 (4) 4.66 (1), 3.48 (2), 2.57 (3), 2.01 (4)
EER 3.39 (1), 2.78 (2) 3.39 (1), 2.78 (2) 3.39 (1), 2.78 (2) 3.39 (1), 2.78 (2) 3.39 (1), 2.78 (2) 3.01 (1), 2.51 (2) 3.01 (1), 2.51 (2) 3.01 (1), 2.51 (2) 3.01 (1), 2.51 (2) 3.01 (1), 2.51 (2) 3.01 (1), 2.51 (2) 2.76 (1), 2.32 (2) 2.76 (1), 2.32 (2) 2.76 (1), 2.32 (2) 2.76 (1), 2.32 (2) 2.76 (1), 2.32 (2) 2.76 (1), 2.32 (2) 3.39 (1), 2.78 (2)
Poznámky (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C) (1) - Stav 1: chladenie Ta 35 °C - LWE 18 °C (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 35 °C (DT = 5 °C)
  (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C) (2) - Stav 2: chladenie Ta 35 °C - LWE 7℃ (DT = 5 °C); kúrenie Ta DB/WB 7 °C/6 °C – LWC 45℃ (DT = 5 °C)
  (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C (3) - Stav 3: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 35 °C
  (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃ (4) - Stav 4: vykurovanie Ta DB -7 °C (RH 85 %) - LWC 45℃